Vivotek WDR Pro Manuel d'utilisateur Page 152

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 209
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 151
VIVOTEK
152 - User's Manual
URL Command Document for All Series
schedule
i<0~(m-1)>_begintime hh:mm 18:00 4/4 Begin time of
schedule mode.
i<0~(m-1)>_endtime hh:mm 06:00 4/4 End time of
schedule mode.
i<0~(m-1)>_win_i<0~2>_enable <boolean> 0 4/4 Enable motion
window.
i<0~(m-1)>_win_i<0~2>_name string[14] <blank> 4/4 Name of motion
window.
i<0~(m-1)>_win_i<0~2>_left 0 ~ 320 0 4/4 Left coordinate of
window position.
i<0~(m-1)>_win_i<0~2>_top 0 ~ 240 0 4/4 Top coordinate of
window position.
i<0~(m-1)>_win_i<0~2>_width 0 ~ 320 0 4/4 Width of motion
detection window.
i<0~(m-1)>_win_i<0~2>_height 0 ~ 240 0 4/4 Height of motion
detection window.
i<0~(m-1)>_win_i<0~2>_objsize 0 ~ 100 0 4/4 Percent of motion
detection window.
i<0~(m-1)>_win_i<0~2>_sensitivity 0 ~ 100 0 4/4 Sensitivity of
motion detection
window.
7.13 Tampering detection settings
Group: tampering_c<0~(n-1)> for n channel product
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enable <boolean> 0 4/4 Enable or disable tamper detection.
duration 10 ~ 600 10 4/4 If tampering value exceeds the ‘threshold’ for
more than ‘duration’ second(s), then tamper
detection is triggered.