Vivotek ND8301 Manuel d'utilisateur Page 208

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 210
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 207
VIVOTEK
208 - User's Manual
Appendix Rebuilding a RAID Volume
If a drive fails, the failure will be indicated by the system fault LED or the Disk Status panel. If a disk drive
fails in a RAID1 volume, rst locate the faulty drive in the Disk Status panel, remove the faulty drive with
a drive of the same capacity and rotation speed.
Note that you must carefully identify the faulty drive. Replacing the wrong drive from a RAID1
volume will result in losing 2 member drives. If a RAID1 volume loses 2 members, all data will be
lost on that volume.
You should be prompted by the message if a hard drive fails or was
removed. An incorrect or abrupt shutdown of the system may also
force the system to rebuild a RAID volume. Data may not have all been
properly distributed to hard drives when inappropirately shut down.
Vue de la page 207
1 2 ... 203 204 205 206 207 208 209 210

Commentaires sur ces manuels

Pas de commentaire